Cabin & home power planning

Plan for a little more independence.

Explore solar, battery storage and generator backup for the way you want to live. Change the loads, choose your runtime and take a planning PDF into your next conversation.

Explore Wolf vacation cabins →
Planning estimatePlanning estimate - not an engineered or approved electrical design. Equipment shown is for comparison; installation, permits, listings and system compatibility need professional review.

Your power plan

See how it works together.

2D concept · not a wiring diagram

Select a component to change it. This diagram describes energy flow; it does not establish wiring, equipment placement or roof fit.

Where is the home, and how will you use it?

The property address sets local sun, cold-weather and elevation data. Only the city, county and state appear in your plan; the street address is not saved, stored or sent anywhere except the address-suggestion lookup.

Choose a suggested address to load local solar and temperature data.

Address search shares what you type with lookup services. Privacy details.

Address search providers

Suggestions use Photon / OpenStreetMap and, for some full addresses, our U.S. Census lookup.

Choose the property address first. Select a Wolf model on the next tab to use its circuit schedule.

How the calculator works & what it does not check

Daily home energy = sum of watts × equivalent hours ÷ 1,000, month by month. Battery demand adds conversion losses and continuous inverter idle draw. Usable storage = nominal capacity × retained capacity × (1 − reserve). Runtime assumes a full battery at the start and repeated average daily use in the design month with no solar or generator contribution.

Solar = panel kW × monthly peak sun hours × (1 − losses). Sun hours come from PVGIS v5.3 (PVGIS-ERA5, 2005–2023) at the nearest grid point to the address, 40° tilt facing south, with terrain horizon. Strings are distributed across enough controllers to stay within nominal PV power and short-circuit current limits. No hourly weather, snow cover, roof geometry, structural loading, fire access or nearby shading model is included.

Inverters are sized to the design month's highest coincident hour: the heat pump at rated input, the large appliances whose sourced hourly schedule (NREL OpenStudio-HPXML / ANSI/RESNET/ICC 301) puts at least twice their average share in that hour, and small loads at their average demand then; with load management only the largest of the range, dryer, water heater and wall heaters runs at once and never below the largest single load and its startup on each leg, per NEC 710.15(A) for stand-alone systems. A backup system without load management carries the full NEC 220.82 calculated load (702.4(B)(2)(a)); with load management, the managed peak (702.4(B)(2)(b)). The backup generator covers that load plus battery charging. The NEC 220.82 figure is shown for the service and feeder. The battery and BMS are checked against the most the inverters can draw. Generator charging uses the design month's average load, the spec sheet's altitude and temperature derating, and the inverter charger and battery limits. Fuel is read along the published 50%/100% points at the derated output. Charger taper, control delays and maintenance downtime are not modeled.

Recommended daily use: EIA RECS 2020 Pacific-division end-use averages (scaled to a two-person household or the floor-area bin), the refrigerator's EnergyGuide label, and degree-day heating and cooling on the model's WSU C3 heat loss with the heat pump's HSPF2/SEER2. Remaining Wolf planning assumptions: two occupants, countertop-appliance and other plug-load energy, bath fan hours, the cabin's occupancy, setback and standby use, the 2x-share rule and 1,500 W countertop appliance in the peak, and the fallback heat loss and heat pump rating when a model has none. This calculator does not perform a permit load calculation, conductor/fuse sizing, grounding/bonding design, fault-current analysis, system listing verification or engineering review. Check critical loads and winter operation with a qualified designer.

Solar radiation and temperature data: PVGIS © European Union, 2001–2026, based on Copernicus ERA5 reanalysis.

Victron off-grid planning resources ↗